Export limit exceeded: 418073 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 418073 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 10569 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (10569 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-42407 | 2026-04-15 | 8.5 High | ||
| Insertion of Sensitive Information into Log File (CWE-532) in the Gallagher Command Centre Alarm Transmitter feature could allow an authenticated Operator to view some security sensitive information to which they have not been granted access. This issue affects: Command Centre Server 9.10 prior to 9.10.2149 (MR4), 9.00 prior to 9.00.2374 (MR5), 8.90 prior to 8.90.2356 (MR6), all versions of 8.80 and prior. | ||||
| CVE-2024-43141 | 1 Rolandbarkerxnauwebdesign | 1 Participants Database | 2026-04-15 | 9.8 Critical |
| Deserialization of Untrusted Data vulnerability in Roland Barker, xnau webdesign Participants Database allows Object Injection.This issue affects Participants Database: from n/a through 2.5.9.2. | ||||
| CVE-2024-43660 | 2026-04-15 | 7.5 High | ||
| The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y). | ||||
| CVE-2024-4369 | 1 Redhat | 1 Openshift | 2026-04-15 | 6.8 Medium |
| An information disclosure flaw was found in OpenShift's internal image registry operator. The AZURE_CLIENT_SECRET can be exposed through an environment variable defined in the pod definition, but is limited to Azure environments. An attacker controlling an account that has high enough permissions to obtain pod information from the openshift-image-registry namespace could use this obtained client secret to perform actions as the registry operator's Azure service account. | ||||
| CVE-2024-43781 | 2026-04-15 | 5.5 Medium | ||
| A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions. | ||||
| CVE-2024-43812 | 1 Kieback\&peter | 10 Ddc4002 Firmware, Ddc4002e Firmware, Ddc4020e Firmware and 7 more | 2026-04-15 | 8.4 High |
| Kieback & Peter's DDC4000 series has an insufficiently protected credentials vulnerability, which may allow an unauthenticated attacker with access to /etc/passwd to read the password hashes of all users on the system. | ||||
| CVE-2024-4471 | 2026-04-15 | 8 High | ||
| The 140+ Widgets | Best Addons For Elementor – FREE for WordPress is vulnerable to PHP Object Injection in versions up to, and including, 1.4.3.1 via deserialization of untrusted input in the 'export_content' function. This allows authenticated attackers, with contributor-level permissions and above, to inject a PHP Object. No POP chain is present in the vulnerable plugin. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code. Thanks, Francesco | ||||
| CVE-2024-44754 | 2026-04-15 | 6.8 Medium | ||
| Cryptographic key extraction from internal flash in Minut M2 with firmware version #15142 allows physically proximate attackers to inject modified firmware into any other Minut M2 product via USB. | ||||
| CVE-2024-44807 | 1 D-zero | 2 Burgereditor, Burgereditor Limited Edition | 2026-04-15 | 5.3 Medium |
| A directory listing issue in the baserCMS plugin in D-ZERO CO., LTD. BurgerEditor and BurgerEditor Limited Edition before 2.25.1 allows remote attackers to obtain sensitive information by exposing a list of the uploaded files. | ||||
| CVE-2024-4733 | 1 Plainware | 1 Shiftcontroller | 2026-04-15 | 7.5 High |
| The ShiftController Employee Shift Scheduling plugin is vulnerable to PHP Object Injection via deserialization of untrusted input via the `hc3_session`-cookie in versions up to, and including, 4.9.57. This makes it possible for an authenticated attacker with contributor access-level or above to inject a PHP Object. No POP chain is present in the vulnerable plugin. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code. | ||||
| CVE-2024-47971 | 2026-04-15 | 6.5 Medium | ||
| Improper error handling in firmware of some SSD DC Products may allow an attacker to enable denial of service. | ||||
| CVE-2024-49396 | 1 Elvaco | 1 Cme3100 Firmware | 2026-04-15 | N/A |
| The affected product is vulnerable due to insufficiently protected credentials, which may allow an attacker to impersonate Elvaco and send false information. | ||||
| CVE-2024-51977 | 2026-04-15 | 5.3 Medium | ||
| An unauthenticated attacker who can access either the HTTP service (TCP port 80), the HTTPS service (TCP port 443), or the IPP service (TCP port 631), can leak several pieces of sensitive information from a vulnerable device. The URI path /etc/mnt_info.csv can be accessed via a GET request and no authentication is required. The returned result is a comma separated value (CSV) table of information. The leaked information includes the device’s model, firmware version, IP address, and serial number. | ||||
| CVE-2024-51984 | 2026-04-15 | 6.8 Medium | ||
| An authenticated attacker can reconfigure the target device to use an external service (such as LDAP or FTP) controlled by the attacker. If an existing password is present for an external service, the attacker can force the target device to authenticate to an attacker controlled device using the existing credentials for that external service. In the case of an external LDAP or FTP service, this will disclose the plaintext password for that external service to the attacker. | ||||
| CVE-2024-52940 | 1 Anydesk | 1 Anydesk | 2026-04-15 | 7.5 High |
| AnyDesk through 8.1.0 on Windows, when Allow Direct Connections is enabled, inadvertently exposes a public IP address within network traffic. The attacker must know the victim's AnyDesk ID. | ||||
| CVE-2024-53544 | 2026-04-15 | 9.8 Critical | ||
| NovaCHRON Zeitsysteme GmbH & Co. KG Smart Time Plus v8.x to v8.6 was discovered to contain a SQL injection vulnerability via the getCookieNames method in the smarttimeplus/MySQLConnection endpoint. | ||||
| CVE-2024-53649 | 2026-04-15 | 6.5 Medium | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices. | ||||
| CVE-2024-6441 | 2026-04-15 | 6.3 Medium | ||
| A vulnerability was found in ORIPA up to 1.72. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file src/main/java/oripa/persistence/doc/loader/LoaderXML.java. The manipulation leads to deserialization. The attack can be launched remotely. Upgrading to version 1.80 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-270169 was assigned to this vulnerability. | ||||
| CVE-2025-0760 | 2026-04-15 | 2.7 Low | ||
| A Credential Disclosure vulnerability exists where an administrator could extract the stored SMTP account credentials due to lack of encryption. | ||||
| CVE-2024-7560 | 1 Codename065 | 1 Newsflash | 2026-04-15 | 7.2 High |
| The News Flash theme for WordPress is vulnerable to PHP Object Injection in all versions up to, and including, 1.1.0 via deserialization of untrusted input from the newsflash_post_meta meta value. This makes it possible for authenticated attackers, with Editor-level access and above, to inject a PHP Object. No known POP chain is present in the vulnerable software. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code. | ||||