| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication. |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| A hardcoded AES key in PMFW may result in a privileged attacker gaining access to the key, potentially resulting in internal debug information leakage. |
| The CS5000 Fire Panel is vulnerable due to a hard-coded password that
runs on a VNC server and is visible as a string in the binary
responsible for running VNC. This password cannot be altered, allowing
anyone with knowledge of it to gain remote access to the panel. Such
access could enable an attacker to operate the panel remotely,
potentially putting the fire panel into a non-functional state and
causing serious safety issues. |
| Precor touchscreen console P62, P80, and P82 could allow a remote attacker (within the local network) to bypass security restrictions, and access the service menu, because there is a hard-coded service code. |
| Precor touchscreen console P82 contains a private SSH key that corresponds to a default public key. A remote attacker could exploit this to gain root privileges. |
| Precor touchscreen console P62, P80, and P82 could allow a remote attacker to obtain sensitive information because the root password is stored in /etc/passwd. An attacker could exploit this to extract files and obtain sensitive information. |
| In KDE libksieve before 23.03.80, kmanagesieve/session.cpp places a cleartext password in server logs because a username variable is accidentally given a password value. |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges.
|
| An high privileged remote attacker can enable telnet access that accepts hardcoded credentials. |
| Use of hard-coded credentials issue exists in Ricoh Streamline NX PC Client ver.3.7.2 and earlier. If this vulnerability is exploited, an attacker may obtain LocalSystem Account of the PC where the product is installed. As a result, unintended operations may be performed on the PC. |
| The configuration file is encrypted with a static key derived from a
static five-character password which allows an attacker to decrypt this
file. The application hashes this five-character password with
the outdated and broken MD5 algorithm (no salt) and uses the first five
bytes as the key for RC4. The configuration file is then encrypted with
these parameters. |
| Forever KidsWatch Call Me KW50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h, and Forever KidsWatch Call Me 2 KW60 R36CW_YDE_S4_A29_2_V1.0_2023.05.24_22.49.44_cob_b have a Hardcoded password vulnerability. |
| "Piccoma" App for Android and iOS versions prior to 6.20.0 uses a hard-coded API key for an external service, which may allow a local attacker to obtain the API key. Note that the users of the app are not directly affected by this vulnerability. |
| Certain models of routers from Billion Electric has hard-coded embedded linux credentials, allowing attackers to log in through the SSH service using these credentials and obtain root privilege of the system. |
| CWE-798: Use of Hard-coded Credentials |
| Ecovacs Home Android and iOS Mobile Applications up to version 3.3.0 contained embedded access keys and secrets for Alibaba Object Storage Service (OSS), leading to sensitive data disclosure. |
| A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers. |
| NVIDIA AIStore contains a vulnerability in AuthN. A successful exploit of this vulnerability might lead to escalation of privileges, information disclosure, and data tampering. |