Search Results (4276 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-40801 1 Siemens 8 Comos, Nx, Simcenter 3d and 5 more 2026-04-15 8.1 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2025-40804 1 Siemens 1 Simatic 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected application exposes a network share without any authentication. This could allow an attacker to access or alter sensitive data without proper authorization.
CVE-2025-40805 1 Siemens 24 Industrial Edge Cloud Device (iecd), Industrial Edge Device Kit, Industrial Edge Own Device (ieod) and 21 more 2026-04-15 10 Critical
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.
CVE-2025-3651 2026-04-15 N/A
Improper Verification of Source of a Communication Channel in Work Desktop for Mac versions 10.8.1.46 and earlier allows attackers to execute arbitrary commands via unauthorized access to the Agent service.  This has been remediated in Work Desktop for Mac version 10.8.2.33.
CVE-2025-36535 1 Automationdirect 1 Mb Gateway 2026-04-15 10 Critical
The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality.
CVE-2025-3659 2026-04-15 N/A
Improper authentication handling was identified in a set of HTTP POST requests affecting the following product families: * Digi PortServer TS - prior to and including 82000747_AA, build date 06/17/2022 * Digi One SP/Digi One SP IA/Digi One IA - prior to and including 82000774_Z, build date 10/19/2020 * Digi One IAP – prior to and including 82000770 Z, build date 10/19/2020 A specially crafted POST request to the device’s web interface may allow an unauthenticated attacker to modify configuration settings.
CVE-2025-36751 1 Growatt 2 Mic3300tl-x, Shinelan-x 2026-04-15 N/A
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
CVE-2025-36754 1 Growatt 1 Shinelan-x 2026-04-15 N/A
The authentication mechanism on web interface is not properly implemented. It is possible to bypass authentication checks by crafting a post request with new settings since there is no session token or authentication in place. This would allow an attacker for instance to point the device to an arbitrary address for domain name resolution to e.g. facililitate a man-in-the-middle (MitM) attack.
CVE-2025-36852 2 Niklas Portmann, Nx 7 Nx-remotecache-azure, Nx-remotecache-custom, Nx-remotecache-minio and 4 more 2026-04-15 N/A
A critical security vulnerability exists in remote cache extensions for common build systems utilizing bucket-based remote cache (such as those using Amazon S3, Google Cloud Storage, or similar object storage) that allows any contributor with pull request privileges to inject compromised artifacts from an untrusted environment into trusted production environments without detection.  The vulnerability exploits a fundamental design flaw in the "first-to-cache wins" principle, where artifacts built in untrusted environments (feature branches, pull requests) can poison the cache used by trusted environments (protected branches, production deployments).  This attack bypasses all traditional security measures including encryption, access controls, and checksum validation because the poisoning occurs during the artifact construction phase, before any security measures are applied.
CVE-2025-3710 2026-04-15 9.8 Critical
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device.
CVE-2025-3711 2026-04-15 9.8 Critical
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device.
CVE-2025-3714 2026-04-15 9.8 Critical
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device.
CVE-2025-3895 1 Jan Syski 1 Megabip 2026-04-15 N/A
Token used for resetting passwords in MegaBIP software are generated using a small space of random values combined with a queryable value. It allows an unauthenticated attacker who know user login names to brute force these tokens and change account passwords (including these belonging to administrators).  Version 5.20 of MegaBIP fixes this issue.
CVE-2025-3621 2026-04-15 9.6 Critical
Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.  * vulnerabilities: * Improper Neutralization of Special Elements used in a Command ('Command Injection') * Use of Hard-coded Credentials * Improper Authentication * Binding to an Unrestricted IP Address The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required.
CVE-2025-32965 2026-04-15 N/A
xrpl.js is a JavaScript/TypeScript API for interacting with the XRP Ledger in Node.js and the browser. Versions 4.2.1, 4.2.2, 4.2.3, and 4.2.4 of xrpl.js were compromised and contained malicious code designed to exfiltrate private keys. Version 2.14.2 is also malicious, though it is less likely to lead to exploitation as it is not compatible with other 2.x versions. Anyone who used one of these versions should stop immediately and rotate any private keys or secrets used with affected systems. Users of xrpl.js should pgrade to version 4.2.5 or 2.14.3 to receive a patch. To secure funds, think carefully about whether any keys may have been compromised by this supply chain attack, and mitigate by sending funds to secure wallets, and/or rotating keys. If any account's master key is potentially compromised, disable the key.
CVE-2025-33024 2026-04-15 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'tcpdump' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-33025 2026-04-15 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-3321 2026-04-15 N/A
A predefined administrative account is not documented and cannot be deactivated. This account cannot be misused from the network, only by local users on the server.
CVE-2025-3322 2026-04-15 N/A
An improper neutralization of inputs used in expression language allows remote code execution with the highest privileges on the server.
CVE-2025-34022 2026-04-15 N/A
A path traversal vulnerability exists in multiple models of Selea Targa IP OCR-ANPR cameras, including iZero, Targa 512, Targa 504, Targa Semplice, Targa 704 TKM, Targa 805, Targa 710 INOX, Targa 750, and Targa 704 ILB. The /common/get_file.php script in the “Download Archive in Storage” page fails to properly validate user-supplied input to the file parameter. Unauthenticated remote attackers can exploit this vulnerability to read arbitrary files on the device, including sensitive system files containing cleartext credentials, potentially leading to authentication bypass and exposure of system information. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-02 UTC.